Globe

Refinery Offshore Platform
Ship Marine Pipe Burn Test

Conley's 90M Series FireProof
and
90MC Series Conductive
Piping Systems for Marine & Refinery Applications

Typical applications include Shipboard Group II Piping Systems, seawater cooling systems, ballast water piping systems, fresh water piping systems, sanitary/drains/scuppers piping systems, vents/sounding piping systems, miscellaneous produced water (oil production) piping systems, fire water systems, fire deluge systems, and general marine piping for ship board and offshore piping systems.

Conley Schedule 90M and 90MC Pipe and Fittings for marine applications have passed the fire endurance tests with:

Products:
  • Schedule 90M Pipe and Fittings from 1" through 20" NPS.
  • Schedule 90MC Conductive Pipe and Fittings from 1" through 20" NPS.

Intended Uses:

  • Marine applications regulated by American Bureau of Shipping (ABS), Lloyd's Register of Shipping (LR), U.S. Coast Guard, and Det Norske Veritas (DNV).
  • Industrial applications in flammable areas, such as refineries.

Ratings:

  • Internal pressure ratings 150, 225, or 250 psi with temperatures to 235° F.
  • Full vacuum external pressure minimum.
  • 90MC Conductive series resistance to earth not to exceed 1 x 106 Ohm.

Codes and Standards Information:

ABS Logo
Type Approval Certificates
No.
02-HS259064-X 90-150
No.
02-HS259064-X 90-225
90M-250
90MC-250

Compliance to the following classifications certified by Certificate No. 02-HS259064-X for Schedule 90M and 90MC 150 psi and by Certificate No. 02-HS259064-X for Schedule 90M-225 and 90MC-225 psi and Schedule 90M-250 and 90MC-250 psi.
4/6.14 of the ABS Rules for Steel Vessels, 4/2.17 of the MODU Rules, and Guide for Facilities on Offshore Installations.
Level 3 (L3) Fire Endurance & hydrostatic evaluation based on IMO Resolution A.753(18), Appendix 2 & ASTM F1173-95.

90M/MC-250 Piping Systems may be used in all L3 Wet/Dry Fire Endurance for Fire Mains and Deluge systems within the limitations of PFM 1-98 & the IMO Res A.753(18).

Intended Service: Shipboard Group II Piping Systems (locations with L3 rating or lower) as follows:
Sea Water and Fresh Water (Potable Water)
Sanitary/Drains/Scuppers
Vents/Sounding

DNV Logo
Type Approval Certificates
No.
K-2397
&
K-1959

Compliance to the following classifications certified by Certificate No. K-2397 for Schedule 90M & K-1959 for Schedule 90MC
Det Norske Veritas' Rules for Classification of Ships
Det Norske Veritas' Type Approval Programme 1-501.1.1999, Fibre Reinforced Thermosetting Plastic Pipes
Det Norske Veritas' Rules for Classification of Mobile Offshore Units

Application:
To be installed according to DNV Rules and Manufacturers Specification. Schedule 90M Piping system is non-conductive, not for installation in gas hazardous area. Schedule 90MC is approved as conductive for installation in gas hazardous area. Piping system is approved to Fire Endurance Level 3 (L3), according to IMO A.753(18), and Low Flame Spread according to ASTM D635.

Lloyd's Logo
Lloyd's Register Type Approval Certificate
No.
02/60002

Compliance to the following classifications certified by Certificate No. 02/60002 for Schedule 90M & Schedule 90MC
LR Rules and Regulations for the Classification of Ships
LR Rules and Regulations for the Classification of Mobile Offshore Units
LR Rules and Regulations for the Classification of Fixed Iffshore Units
IMO Resolution A.753(18), Appendix 2 & ASTM F1173-95 (Fire Endurance and Hydrostatic Evaluation)
Fire performance requirements for services requiring L3 Rating

Application:
Shipboard piping systems, piping system for seawater, fresh water, sanitary/drains/scuppers, vents/sounding, miscellaneous, firewater system, fire deluge systems, general marine piping for shipboard & offshore piping systems.

USCG Logo
Type Approval Certificates
No.
16714/164.141

Compliance to the following classifications certified by Certificates No. 16714/164.141 for:
  • Schedule 90MC-150
  • Schedule 90MC-225
  • Schedule 90MC-250
  • Schedule 90MC-150
  • Schedule 90MC-225
  • Schedule 90MC-250

Level 3 (L3) Fire Endurance and L3 Wet/Dry Fire Endurance for Fire Mains and Deluge Systems
IMO Resolution A.753(18), Application of Plastic Pipes on Ships
USCG PFM 1-98, Fire Performance Requirements for Plastic Pipe per A.753(18)

Application:
Meeting the Level 3 (L3) and L3 Wet/Dry Fire Endurance requirements as specified.

Contact us: sales@conleyfrp.com

Conley Corporation
2795 East 91st Street
Tulsa, Oklahoma USA 74137
1-800-331-5502 or (918) 299-5051 / Fax (918) 299-5907

 

Copyright © April 21, 2004 Conley Corporation
All Rights Reserved.