Conley's 90M Series
Proof
and 90MC Series Conductive
Piping Systems for Marine & Refinery Applications
Typical applications
include Shipboard Group II Piping Systems, seawater cooling
systems, ballast water piping systems, fresh water piping
systems, sanitary/drains/scuppers piping systems, vents/sounding
piping systems, miscellaneous produced water (oil production)
piping systems, fire water systems, fire deluge systems, and
general marine piping for ship board and offshore piping systems.
Conley Schedule 90M and 90MC Pipe and Fittings for marine applications
have passed the fire endurance tests with:
Zero leakage
Zero material
degradation
Low Flame
Spread = <24.5 (ASTM E-84)
Low Smoke
Development = <123 (ASTM E-84) as compared to normal
FRP (GRP) smoke development of 2000
| Products: |
- Schedule 90M Pipe and
Fittings from 1" through 20" NPS
- Schedule 90MC
Conductive Pipe and Fittings from 1" through
20" NPS
Series
90MX with low flame spread and smoke &
toxicity for USCG requirements
All
Series 90 Piping Systems are soon the become Type
Approved (ABS pending)
|
Intended
Uses:
|
- Marine applications
regulated by American Bureau of Shipping (ABS),
Lloyd's Register of Shipping (LR), U.S. Coast
Guard, and Det Norske Veritas (DNV)
- Industrial
applications in flammable areas, such as
refineries
- Firewater and Deluge
piping systems
- Potable water systems
|
Ratings:
|
- Internal pressure
ratings 150, 225, or 250 psi with temperatures to
235° F
- Full vacuum external
pressure minimum
- 90MC Conductive series
resistance to earth not to exceed 1 x 106
Ohm
90MX
products meet the criteria for low flame spread
and smoke & toxicity
- All fire endurance
testing by Southwest Research Institute in San
Antonio, Texas
|
Codes and Standards
Information:

Type Approval
Certificates
No. 05-QA259064-X3
|
Compliance to
the following classifications:
- 2004 Steel
Vessel Rules 1-1-4/3.7, 2001 MODU 4-2-2/7 Rules,
and Guide for Facilities on Offshore
Installations.
- Fire
Endurance & hydrostatic evaluation based on
IMO Resolution A.753(18), Appendix 2 & ASTM
F1173-95.
- USCG PFM
1-98
All Series 90M/MC Piping Systems may be
used in L3 Wet/Dry Fire Endurance for Fire Mains and
Deluge systems within the limitations of PFM 1-98 &
the IMO Res A.753(18).
Intended
Service: Shipboard Group II Piping Systems (locations
with L3 rating or lower) as follows:
Sea Water and Fresh Water (Potable Water)
Firewater and Deluge Systems
Sanitary/Drains/Scuppers
Vents/Sounding
Fire mains and
deluge systems for Marine and Offshore Installations per
USCG PFM 1-98 or other applications that require IMO
A.753(18) Level 3 or LEvel 3 Wet/Dry (L3 W/D) fire
endurance rating or less.
|

Type Approval
Certificates
No. K-2397
& K-2752
|
Compliance to
the following classifications:
- Det Norske
Veritas' Rules for Classification of Ships
- Det Norske
Veritas' Type Approval Programme 1-501.1.1999,
Fibre Reinforced Thermosetting Plastic Pipes
- Det Norske
Veritas' Rules for Classification of Mobile
Offshore Units
Application:
To be installed according to DNV Rules and
Manufacturers Specification. Schedule 90M Piping system
is non-conductive, not for installation in gas hazardous
area. Schedule 90MC is approved as conductive for
installation in gas hazardous area. Piping system is
approved to Fire Endurance Level 3 (L3), according to IMO
A.753(18), and Low Flame Spread according to ASTM D635.
|

Type Approval Certificate
No. 02/60002
|
Compliance to
the following classifications:
- LR Rules
and Regulations for the Classification of Ships
- LR Rules
and Regulations for the Classification of Mobile
Offshore Units
- LR Rules
and Regulations for the Classification of Fixed
Iffshore Units
- IMO
Resolution A.753(18), Appendix 2 & ASTM
F1173-95 (Fire Endurance and Hydrostatic
Evaluation)
Fire performance requirements for services
requiring L3 Rating
Application:
Shipboard piping systems, piping system for
seawater, fresh water, sanitary/drains/scuppers,
vents/sounding, miscellaneous, firewater system, fire
deluge systems, general marine piping for shipboard &
offshore piping systems.
|

Type Approval
Certificates
No. 16714/164.141-1
No. 16714/164.141-2
|
Compliance to
the following classifications:
- Level 3
(L3) Fire Endurance and L3 Wet/Dry Fire Endurance
for Fire Mains and Deluge Systems
- IMO
Resolution A.753(18), Application of Plastic
Pipes on Ships
- USCG PFM
1-98, Fire Performance Requirements for Plastic
Pipe per A.753(18)
Application:
Meeting the Level 3 (L3) and L3 Wet/Dry Fire
Endurance requirements as specified.
Series 90MX meet the criteria for low flame spread spread
amd smoke & tocxicity.
|
Contact us:
sales@conleyfrp.com
Tulsa, Oklahoma USA 74137
1-800-331-5502 or (918) 299-5051 /
Fax (918) 299-5907
Copyright ©
November 20, 2006 Conley Corporation