Conley's Schedule 90M Pipe
undergoing
30 Minute Fire Endurance Test
|
- Conley
Corporation's Internationally Certified by ABS
& DNV
Schedule
90M
Piping Systems with Fire Protective Coatings
have PASSED the ASTM F 1173 Fire Endurance Test! This
test procedure is based on the IMO
Assembly Resolution A.753(18). This
test method subjects a pipe/fitting sample to a constant
36,011 Btu/(hr-ft2)
net heat flux (up to 1800 degrees F flame temperature)
for 30 minutes duration and then subjects the sample to a
15 minute hydrostatic leak test at 150 psig. This test
gives a purchaser of fiberglass pipe and fittings the
ability to determine the fire resistance of a fiberglass
piping system when filled with water. This is just one of
the special requirements for offshore platforms and
marine application piping systems.